-40%

high precision LCR meter Dual LCD Display 100Hz 100K 0.3% USB RS232 made taiwan

$ 343.72

Availability: 99 in stock
  • Restocking Fee: No
  • Model: RS232
  • Item must be returned within: 14 Days
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money Back
  • Brand: aidetek
  • MPN: RS232
  • Condition: New
  • Country/Region of Manufacture: China

    Description

    high precision LCR meter Dual LCD Display 100Hz 100K 0.3% USB RS232 made taiwan
    Description
    high precision LCR meter Dual LCD Display 100K USB RS232
    Dual LCD Display.
    Capacitance, Resistance, Impedance, Inductance, Quality Factor,
    Dissipation Factor Phase Angle.
    Auto Detect Function.
    Open Circuit/Short Circuit Compassion.
    Operation Frequency 100Hz to 100KHz.
    Basic Accuracy: 0.3%
    Measurement Voltage Fixed at 0.6Vrms.
    LCR-900 was designed for Capacitance, Resistance, Inductance,
    Dissipation Factor, Quality Factor, Phase Angle, Impedance etc
    measurement. Operation frequency from 100Hz to 100KHz, Basic
    measurement accuracy, 0.3%. Dual LCD display, Measurement
    voltage fixed at 0.6V auto-detect function and Open circuit / short circuit
    compassion.
    Primary Measurement display:
    DCR: DC resistance
    Lp: Parallel Inductance
    Ls: Serial Inductance
    Cp: Parallel Capacitance
    Cs: Serial Capacitance
    Rp: Parallel Resistance
    Rs: Serial Resistance
    3. Secondary Measurement Display
    L / C mode:
    θ: Phase Angle
    D: Dissipation Factor
    Q: Quality factor
    Rp: Parallel Impedance
    ESR: Serial Impedance
    4. Impedance factor
    LCR-900 provided both DC and AC impedance measurement.
    The impedance measurement was very important for the electronic
    component, and the characteristic of the material of the parts.
    When show the impedance by Vector,(Z), set the Real Resistance as
    X axis and the Imaginary Reactance as Y axis
    Specifications:
    1. Power Source:
    115V (110V ~ 120v) 50/60Hz: Fuse 600mA
    230V (220V ~ 240V) 50/60Hz: Fuse 300mA
    2. Operation Environment:
    Temperature: 0°C ~ 40°C
    Humidity: 20% ~ 80%
    3. Storage:
    Temperature: -20°C ~ 70°C
    Humidity: 0% ~ 90%
    4. Accessory:
    Power Cord, Operation manual, Test Lead RP-92(BNC Plug to Clip) x
    1.
    Option:
    RP-92 (BNC Plug to pin, for SMD component use)  ( optional, by adding .00)
    5. LCD Display:
    Factor Range
    R 0.000 Ω to 9999 MΩ
    L 0.000 uH to 9999 kH
    C 0.000 pF to 9999 F
    DCR 0.000 Ω to 9999 MΩ
    ESR 0.000 Ω to 9999 Ω
    Rp 0.000 Ω to 9999 Ω
    D 0.000 to 9999
    Q 0.000 to 9999
    θ - 90° to + 90°
    6. Accuracy(Ae)
    Impedance Accuracy ( T=18 ~ 28°C )
    Freq./Z DCR 100/120Hz 1kHz 10kHz 100kHz
    0.1-1Ω 1.0%+5d 1.0%+5d 1.0%+5d 1.0%+5d 2.0%+5d
    1-10Ω 0.5%+3d 0.5%+3d 0.5%+3d 0.5%+3d 1%+5d
    10-100kΩ 0.3%+2d 0.3%+2d 0.3%+2d 0.3%+2d 0.5%+3d
    100k-1MΩ 0.5%+3d 0.5%+3d 0.5%+3d 0.5%+3d 1%+5d
    1M-20MΩ 1.0%+5d 1.0%+5d 1.0%+5d 2.0%+5d
    20M-200MΩ 2.0%+5d 2.0%+5d 2.0%+5d N/A
    2.0%+5d
    (1-2MΩ)
    Remark D < 0.1
    If D > 0.1, the accuracy should be multiplied by 1+ D^2
    Zc = 1/2πfC if D<<0.1 in capacitance mode
    Zl = 2πfL if D<<0.1 in inductance mode
    Sub-display parameter accuracy
    Ae = impedance accuracy
    Definition: Q = 1/D
    Rp = ESR(or Rs) x (1+1/D^2)
    (1) D value accuracy De = ±Ae x (1+D)
    (2) ESR accuracy Re = ±Zm x Ae(Ω)
    ie, Zm = impedance calculate by 1/2πfC or 2πfL
    (3) Phase angle θ accuracy θe = ±(180/π) x Ae(deg)
    Operating Instruction:
    NOTE:.
    LCR-900 have 2 power switch. Line Power Switch○25 on the rear panel
    for the transformer and then the Power Switch○3 Key on the front panel
    for the operation system.
    Switch “ON” the Line Power Switch○25 on the rear panel then press the
    Power Switch○3 key on the front panel to light the LCD.
    1. Open Circuit / Short Circuit calibration:
    LCR-900 provide Open Circuit∕Short Circuit calibration function so
    that you can measure High resistance and low resistance more
    accuracy.
    (1) Open Circuit
    Set the measuring terminal at “OPEN” condition, press CAL○6 key 2
    sec, the main LCD will display 『Open』, than press CAL○6 again to
    start the open circuit calibration, to calibration will need about 30sec,
    after you have hear “Bi-“ and the LCD will display 『PASS』, the
    LCR-900 have finished the Open Circuit calibration automatically.
    (2) Short Circuit
    After Open circuit calibration,press CAL○6 key 2 sec again,the main
    LCD will display『Srt』,and press CAL○6 key again to start the Short
    circuit calibration, the same as Open Circuit Calibration, it need 30sec.
    and after “Bi-“, the LCD will display 『PASS』.
    2. Relative Value Mode:
    Press REL○13 key to enter the “ Relative Value Mode” after you had
    key in the standard value from the Digits○15 key. Press Enter○17 key.
    If the unit must be changed press Range○14 key to change the unit.
    Then Insert the unit to be measured. The Second LCD will display the
    different between the standard value and the measuring value in “%”.
    13
    The equation are as the following:
    Difference value (%) = | measuring value – standard value | / standard
    value x 100%
    NOTE: If the difference value are high than 9999%. The LCD will
    display『----』only.
    3. Sorting Function Mode:
    Press SORT○11 key to enter the sorting function Mode. Key in the max.
    difference value (%) and press Enter○17 key. Then key in the standard
    value and the units. Press Enter○17 key. After your have connect the
    Measuring object. Press Test○12 key. The Second LCD will display
    『PASS』 or 『FAIL』.
    4. Display Hold Mode:
    Press HOLD○10 key. LCR-900 will enter the Display Hold mode. On the
    upper side of the main LCD will display 『HOLD』, The display value on
    the LCD will be kept un changed.
    5. Auto Range Mode:
    Press FUNC○4 key to enter the auto range mode, the upper side of
    the main LCD will display『AUTO LCR』, LCR-900 will detect the object
    been measured and set the range to match it automatically.
    Included what kind and the value etc.
    6. Measuring Frequency:
    Press FREQ○5 key to select the measuring frequency, the range can
    be 1kHz, 10kHz,100kHz, 100Hz,120Hz 5 ranges.
    7. DC Resistance Measurement:
    Press FUNC○4 key to change the LCR-900 range till the upper side of
    the main LCD display 『DCR』, the LCR-900 was under “DC Resistance
    Measuring Mode ”.
    14
    8. Equivalent Impedance of Serial or Parallel circuit:
    Press FUNC○4 key to change the range till the upper side of the main
    LCD display『AUTO』, the LCP-900 will select “ Serial Equivalent
    Resistance” or “Parallel Equivalent Resistance” mode automatically.
    Or press SER/PAL○9 key LCR-900 will swift to manual control the
    output mode as “Serial Equivalent Resistance” or “Parallel Equivalent
    Resistance” mode.
    The Display of the various Equivalent Impedance is as the following:
    Equivalent Impedance Mode Main LCD Display
    Inductor parallel mode Lp
    Capacitor parallel mode Cp
    Resistor parallel mode Rp
    Inductor Serial mode Ls
    Capacitor Serial mode Cs
    Resistor Serial mode Rs
    DC Equivalent impedance DCR
    9. Resistance Measurement
    Upon the Difference, equivalent system “Resistance Measurement”
    can be separated as Serial Mode (Rs, Serial Mode) and Parallel Mode
    (Rp,Parallel Mode), user can press FUNC○4 key to set the range to
    “ R “ position. The LCR-900 will select Rp or Rs automatically. Or press
    SER/PAL○9 key. The Lcr-900 will swift to manual operation to
    measure under Rp or Rs.
    10. Capacitance Measurement
    The same as Resistance Measurement. Upon the equivalent System.
    “Capacitance measurement” can be separated as Serial Mode (Cs,
    Serial Mode) and Parallel Mode(Cp, Parallel Mode), press FUNC○4
    Key to “ C “ position, the LCR-900 will select Cp or CS automatically
    Or press SER/PAL○9 key to select Cp or Cs mode and then press
    D/Q/Θ/ESR○7 key to select D/Q/Θ/ESR factor 。
    NOTE: D/Q/Θ/ESR can not be selected under “AUTO “mode. The
    factor will be fixed at the time it been under “AUTO” mode.
    11. Inductance Measurement
    The same as Capacitance Measurement. “Inductance measurement”
    can be separated as (Ls,Serial Mode) and (Lp,Parallel Mode), press
    FUNC○4 key to “L” Position,The LCR-900 will be set under
    “AUTO” mode. As the Capacitance, press SER/PAL○9 key to manual
    mode and press D/Q/Θ/ESR○7 key to select D/Q/Θ/ESR factor.。
    NOTE:
    D/Q/θ/ESR can not be selected under “AUTO” mode. As capacitance
    measurement.。
    12. Connect To Computer
    Refer to the appendix. Key in the RS-232(USB) code to your computer
    and Connect the LCR-900 to your computer by RS-232(USB) cable.
    Press PC○8 key, the second LCD will display『RS232』, the LCR-900
    been connect to your computer. The output of the measuring result will
    transfer to the computer.
    Shipping: ship from Taiwan by post office with track #, 8-16 business days, thank you
    Payment
    Paypal
    eBay Cross Border Trade powered by Channel Effect